A Florida product approval spells out how a product can be installed, including spans, design pressures, anchors and attachment details. Real jobs do not always line up with those details.
If you install hurricane shutters, hurricane screens or aluminum products, these are five questions that come up when the approval does not quite fit the job.
1. The opening is bigger than the approval allows. Am I stuck?
Not always. Site-specific engineering may be an option, but it depends on the product, the loads, and what the approval and supporting test information allow. We need to review your site-specific condition before saying whether the installation can work.
An opening dimension alone does not tell the whole story. Where that opening sits on the floor plan and what supports it matter too.
2. Do I just need a letter?
Sometimes a signed and sealed deviation letter is enough. Other jobs need calculations, connection details or drawings as well. The quote should tell you what is included before the work starts.
For example, a special attachment to an existing wall may need more than a statement that the product is suitable. The reviewer may also need the connection detail and the calculations behind it.
3. What if the product approval is expired?
Send it for review, but do not assume a letter fixes the expiration. We need to check the approval status, the applicable code requirements and the documents available for the product before saying whether we can help.
4. Will the building department accept it?
Acceptance is the building department’s decision. Our job is to prepare a clear engineering package that addresses the site condition and the reviewer’s comment. If you already have a permit comment, send the actual wording so we can see what is being requested.
5. How fast can you turn it around?
It depends on what needs to be checked. A straightforward attachment review may take less work than a span analysis with several connections. Tell us your deadline and we will give you a realistic turnaround with the price.
What does a sample job look like?
The hurricane shutter sample below shows a review of an 80-inch-wide by 102-inch-high installation. The package includes a letter, opening design pressures, special attachment details and supporting connection calculations.
That is why we ask to see the job details first. The scope can be a letter, or it can be a letter backed by drawings and calculations. These samples show the difference more clearly than a list of services.
View the sample letters
These examples are for reference, not for use on another installation.
Got a job that does not fit the approval?
Visit our Florida Product Approval Deviation Letters & Site-Specific Engineering page for the full document checklist and the form to send your job for review. Or call (941) 391-5980.